New Approach for Estimating Hydraulic Permeability Coefficient and the Removal Rate Capacity of the Membrane

In this paper, a new approach for estimating the hydraulic permeability coefficient of Spiegler-Kedem model has been proposed and verified. Using this new method, estimated flux errors have been decreased in comparison to other laboratory methods. In addition to that, by using the estimated parameter, an imaginary rejection coefficient for a perfect membrane has been estimated which is beneficial to increase insights of membrane makers to make a higher quality membrane.

View PDF

Author: Mohammad Hadian